<%NUMBERING1%>.<%NUMBERING2%>.<%NUMBERING3%> PRTG Manual: NetApp SnapMirror Sensor

The NetApp SnapMirror sensor monitors SnapMirror relationships of a NetApp cDOT or ONTAP storage system accessing the application programming interface (API) via the Simple Object Access Protocol (SOAP).

The sensor can show the following:

  • Health status (healthy yes or no)
  • Transfer status (relationship status returned from the API)
    • Ok: idle, transferring, checking, quiescing, quiesced, queued, preparing, finalizing, aborting
    • Warning: unknown, breaking
  • Lag transfer duration
  • Relationship type
    • Ok: mirror, vault, mirror and vault
    • Error: unknown
  • Size of last transfer
  • Duration of last transfer
  • Time stamp of last transfer
  • Number of resync fails per second
  • Number of update fails per second
  • Mirror state
    • Ok: snapmirrored
    • Warning: uninitialized
    • Error: broken-off, unknown
NetApp SnapMirror Sensor

NetApp SnapMirror Sensor

Remarks

  • icon-betaThis sensor is in beta status. The operating methods and the available settings can change at any time. Do not expect that all functions work properly, or that this sensor works as expected at all. Be aware that this sensor can be removed from PRTG at any time.
  • Requires .NET 4.7.2 or later on the probe system.
  • The ONTAPI user account that you use with this sensor needs access to the DATA ONTAP API (ONTAPI) so that the sensor can request data from it. The access is enabled by default.
  • For this sensor, read-only user rights are sufficient for the ONTAPI user account that you use to access ONTAPI. Modify or add this user with a suitable role in the console under Cluster | ClusterX | Configuration | Security | Users
  • This sensor supports NetApp cDOT as of version 8.3 and NetApp ONTAP as of version 9.0.
  • This sensor supports the IPv6 protocol.
  • You can define NetApp API credentials (User and Password) in the Credentials for Windows Systems settings of the parent device. This way, you do not have to individually enter credentials for each NetApp sensor that you add to the same device.
  • This sensor uses lookups to determine the status values of one or more channels. This means that possible states are defined in a lookup file. You can change the behavior of a channel by editing the lookup file that the channel uses. For details, see section Define Lookups.

Requirement: .NET Framework

This sensor requires the Microsoft .NET Framework. .NET 4.7.2 or later must be installed on the probe system (on every cluster node, if on a cluster probe). If the framework is missing, you cannot create this sensor.

icon-square-cyanFor more information, see the Knowledge Base: Which .NET version does PRTG require?

Requirement: Enabled ONTAPI Access

NetApp sensors require access to ONTAPI for the utilized user account. This is enabled by default. If access is disabled, locally use the following command on the cluster console to enable ONTAPI access for the user:

services web> modify -vserver clusterd -name ontapi -enabled true

Add Sensor

The Add Sensor dialog appears when you manually add a new sensor to a device. It only shows the setting fields that are required for creating the sensor. Therefore, you do not see all setting fields in this dialog. You can change (nearly) all settings in the sensor's Settings tab later.

PRTG performs a meta-scan before you can actually add this sensor and requires basic information for this scan in advance. Provide the requested information in the appearing dialog box. During the scan, PRTG recognizes all items available for monitoring based on your input. The following settings differ in comparison to the sensor's Settings tab.

Select the SnapMirrors that you want to monitor. PRTG creates one sensor for each SnapMirror that you select in the Add Sensor dialog. The settings you select are valid for all sensors that you create when you finish this dialog. The following settings in the Add Sensor dialog differ in comparison to the sensor's Settings tab.

NetApp Specific

SnapMirrors

Select the SnapMirrors that you want to add a sensor for. You see a list with the names of all items that you can monitor. Add check marks in front of the respective lines to select the desired items. You can also use the check box in the table header to select all items or cancel the selection.

icon-i-round-bluePRTG creates one sensor for each selection.

Sensor Settings

Click the Settings tab of a sensor to change its settings.

icon-i-round-blueUsually, a sensor connects to the IP Address or DNS Name of the parent device on which you created the sensor. See the device settings for details. For some sensors, you can explicitly define the monitoring target in the sensor settings. See below for details on available settings.

Basic Sensor Settings

Sensor Name

Enter a meaningful name to identify the sensor. By default, PRTG shows this name in the device tree, as well as in alarms, logs, notifications, reports, maps, libraries, and tickets.

Parent Tags

Shows tags that this sensor inherits from its parent device, group, and probe. This setting is shown for your information only and cannot be changed here.

Tags

Enter one or more tags, separated by spaces or commas. You can use tags to group sensors and use tag–filtered views later on. Tags are not case sensitive. We recommend that you use the default value.

There are default tags that are automatically predefined in a sensor's settings when you add a sensor. See section Default Tags below.

You can add additional tags to the sensor if you like. Other tags are automatically inherited from objects further up in the device tree. These are visible above as Parent Tags.

icon-i-round-blueIt is not possible to enter tags with a leading plus (+) or minus (-) sign, nor tags with parentheses (()) or angle brackets (<>).

Priority

Select a priority for the sensor. This setting determines where the sensor is placed in sensor lists. A sensor with a top priority is at the top of a list. Choose from one star (low priority) to five stars (top priority).

Default Tags

netapp, cdot, ontap, soap

NetApp Connection

NetApp Credentials

Specify which credentials you want to use to connect to the NetApp API:

  • Use explicit credentials: Select this option if you want to use individual NetApp API credentials with this sensor.
  • Use Windows credentials from parent device: If you select this option, the sensor uses the credentials (User and Password) that you entered in the parent device settings in section Credentials for Windows Systems. Defining credentials in the parent device is useful if you add several NetApp sensors to this device because you do not have to individually enter credentials for each NetApp sensor.

Username

This field is only visible if you select Use explicit credentials above. Enter a username for access to the NetApp API. Read-only rights for this ONTAP user account are sufficient. Enter a string.

Password

This field is only visible if you select Use explicit credentials above. Enter the password of the user that you entered above for access to the NetApp API. Enter a string.

Port

Enter a port number on which you can access the NetApp API. Enter an integer value. The default port is 443.

Transport Type

Define if the connection to the NetApp API is Secure Sockets Layer (SSL)/Transport Layer Security (TLS) secured:

  • HTTP: Use an unsecured HTTP connection.
  • HTTPS: Use a SSL/TLS-secured connection to the defined port to send the query.

Timeout (Sec.)

Enter a timeout in seconds for the request. If the reply takes longer than this value, the sensor cancels the request and shows a corresponding error message. Enter an integer value. The maximum value is 900 seconds (15 minutes).

NetApp Specific

NetApp SnapMirrors

Shows the SnapMirror that this sensor monitors. Once you have created the sensor, you cannot change this value. It is shown for reference purposes only. If you need to change this value, add the sensor anew.

Debug Options

Sensor Result

Define what PRTG does with the sensor results:

  • Discard sensor result: Do not store the sensor result.
  • Write sensor result to disk (file name: Result of Sensor [ID].txt): Store the last result received from the sensor to the \Logs\sensors subfolder of the PRTG data directory on the probe system (master node, if in a cluster). File names: Result of Sensor [ID].txt and Result of Sensor [ID].Data.txt. This is for debugging purposes. PRTG overwrites these files with each scanning interval.

icon-prtg-on-demandThis option is not available when the sensor runs on the hosted probe of a PRTG hosted by Paessler instance.

Sensor Display

Primary Channel

Select a channel from the list to define it as the primary channel. In the device tree, the last value of the primary channel is always displayed below the sensor's name. The available options depend on what channels are available for this sensor.

icon-i-round-blueYou can set a different primary channel later by clicking the pin symbol of a channel on the sensor's Overview tab.

Graph Type

Define how different channels are shown for this sensor:

  • Show channels independently (default): Show a graph for each channel.
  • Stack channels on top of each other: Stack channels on top of each other to create a multi-channel graph. This generates a graph that visualizes the different components of your total traffic.
    icon-i-round-blueThis option cannot be used in combination with manual Vertical Axis Scaling (available in the channel settings).

Stack Unit

This field is only visible if you enable Stack channels on top of each other as Graph Type. Select a unit from the list. All channels with this unit are stacked on top of each other. By default, you cannot exclude single channels from stacking if they use the selected unit. However, there is an advanced procedure to do so.

Inherited Settings

By default, all of the following settings are inherited from objects that are higher in the hierarchy and should be changed there if necessary. Often, best practice is to change them centrally in the root group settings. For more information, see section Inheritance of Settings. To change a setting for this object only, disable inheritance by clicking the button next to inherit from under the corresponding setting name. You then see the options described below.

Scanning Interval

Click inherited_settings_button to interrupt the inheritance. See section Inheritance of Settings for more information.

Scanning Interval

Select a scanning interval (seconds, minutes, or hours). The scanning interval determines the amount of time that the sensor waits between two scans. You can change the available intervals in the system administration on PRTG on premises installations.

If a Sensor Query Fails

Define the number of scanning intervals that the sensor has time to reach and check a device again in case a sensor query fails. Depending on the option that you select, the sensor can try to reach and check a device again several times before the sensor shows a Down status. This can avoid false alarms if the monitored device only has temporary issues. For previous scanning intervals with failed requests, the sensor shows a Warning status. Choose from:

  • Set sensor to down immediately: Set the sensor to a Down status immediately after the first failed request.
  • Set sensor to warning for 1 interval, then set to down (recommended): Set the sensor to a Warning status after the first failed request. If the following request also fails, the sensor shows an error.
  • Set sensor to warning for 2 intervals, then set to down: Set the sensor to a Down status only after three consecutively failed requests.
  • Set sensor to warning for 3 intervals, then set to down: Set the sensor to a Down status only after four consecutively failed requests.
  • Set sensor to warning for 4 intervals, then set to down: Set the sensor to a Down status only after five consecutively failed requests.
  • Set sensor to warning for 5 intervals, then set to down: Set the sensor to a Down status only after six consecutively failed requests.

icon-i-round-blueSensors that monitor via Windows Management Instrumentation (WMI) always wait at least one scanning interval before they show a Down status. It is not possible to immediately set a WMI sensor to a Down status, so the first option does not apply to these sensors. All other options can apply.

icon-i-round-blueIf you define error limits for a sensor's channels, the sensor immediately shows a Down status. No "wait" option applies.

icon-i-round-blueIf a channel uses lookup values, the sensor immediately shows a Down status. No "wait" options apply.

Schedules, Dependencies, and Maintenance Window

icon-i-round-blueYou cannot interrupt the inheritance for schedules, dependencies, and maintenance windows. The corresponding settings from the parent objects are always active. However, you can define additional settings here. They are active at the same time as the parent objects' settings.

Schedule

Select a schedule from the list. Schedules can be used to monitor for a certain time span (days or hours) every week.

icon-square-cyanYou can create schedules, edit schedules, or pause monitoring for a specific time span. For more information, see section Account Settings—Schedules.

icon-i-round-blueSchedules are generally inherited. New schedules are added to schedules that you already set up, so all schedules are active at the same time.

Maintenance Window

Specify if you want to set up a one-time maintenance window. During a maintenance window, the selected object and all child objects are not monitored. They are in a Paused status instead. Choose between:

  • Not set (monitor continuously): No maintenance window is set and monitoring is always active.
  • Set up a one-time maintenance window: Pause monitoring within a maintenance window. You can define a time span for a monitoring pause below and change it even for an active maintenance window.

icon-i-round-blueTo terminate an active maintenance window before the defined end date, change the time entry in Maintenance Ends to a date in the past.

Maintenance Begins

This field is only visible if you enable Set up a one-time maintenance window above. Use the date time picker to enter the start date and time of the maintenance window.

Maintenance Ends

This field is only visible if you enable Set up a one-time maintenance window above. Use the date time picker to enter the end date and time of the maintenance window.

Dependency Type

Define a dependency type. You can use dependencies to pause monitoring for an object depending on the status of a different object. You can choose from:

  • Use parent: Use the dependency type of the parent object.
  • Select a sensor: Use the dependency type of the parent object. Additionally, pause the current object if a specific sensor is in a Down status or in a Paused status caused by another dependency.
  • Master sensor for parent: Make this sensor the master object for its parent device. The sensor influences the behavior of its parent device: If the sensor is in a Down status, the device is paused. For example, it is a good idea to make a Ping sensor the master object for its parent device to pause monitoring for all other sensors on the device in case the device cannot even be pinged. Additionally, the sensor is paused if the parent group is paused by another dependency.

icon-i-round-blueTo test your dependencies, select Simulate Error Status from the context menu of an object that other objects depend on. A few seconds later, all dependent objects are paused. You can check all dependencies under Devices | Dependencies in the main menu bar.

Dependency

This field is only visible if you enable Select a sensor above. Click the Search button and use the object selector to select a sensor on which the current object will depend.

Dependency Delay (Sec.)

This field is only visible if you enable Select a sensor above. Define a time span in seconds for dependency delay.

After the master sensor for this dependency comes back to an Up status, monitoring of the dependent objects is additionally delayed by the defined time span. This can prevent false alarms, for example, after a server restart, by giving systems more time for all services to start up. Enter an integer value.

icon-i-round-redThis setting is not available if you set this sensor to Use parent or to be the Master sensor for parent. In this case, define delays in the parent device settings or in its parent group settings.

Access Rights

Click inherited_settings_button to interrupt the inheritance. See section Inheritance of Settings for more information.

User Group Access

Define the user groups that have access to the sensor. You see a table with user groups and group access rights. The table contains all user groups in your setup. For each user group, you can choose from the following group access rights:

  • Inherited: Inherit the access rights settings of the parent object.
  • No access: Users in this user group cannot see or edit the sensor. The sensor neither shows up in lists nor in the device tree.
  • Read access: Users in this group can see the sensor and view its monitoring results. They cannot edit any settings.
  • Write access: Users in this group can see the sensor, view its monitoring results, and edit its settings. They cannot edit its access rights settings.
  • Full access: Users in this group can see the sensor, view its monitoring results, edit its settings, and edit its access rights settings.

icon-square-cyanFor more details on access rights, see section Access Rights Management.

More

icon-square-blueKNOWLEDGE BASE

Which .NET version does PRTG require?

Edit Channels

To change display settings, spike filtering, and limits, switch to the sensor's Overview tab and click the gear icon of a specific channel. For detailed information, see section Sensor Channel Settings.

Notification Triggers

Click the Notification Triggers tab to change notification triggers. For detailed information, see section Sensor Notification Triggers Settings.

Others

For more general information about settings, see section Object Settings.

Sensor Settings Overview