<%NUMBERING1%>.<%NUMBERING2%>.<%NUMBERING3%> PRTG Manual: SNMP Trap Receiver Sensor
The SNMP Trap Receiver sensor receives and analyzes Simple Network Management Protocol (SNMP) traps.
The sensor can show the following:
- Overall number of received traps per second
- Trap messages categorized as "warning" per second
- Trap messages categorized as "error" per second
- Number of dropped trap packets per second on the SNMP trap collector port
- The actual trap messages
SNMP Trap Receiver Sensor
Sensor in Other Languages
Dutch: SNMP Trap-ontvanger, French: Récepteur de trap SNMP, German: SNMP-Trap-Empfänger, Japanese: SNMP トラップ受信, Portuguese: Receptor de trap SNMP, Russian: Приемник ловушек SNMP, Simplified Chinese: SNMP 陷阱接收程序, Spanish: Receptor SNMP Trap
Remarks
You cannot add this sensor to the hosted probe of a PRTG hosted by Paessler instance. If you want to use this sensor, add it to a remote probe device.
PRTG hosted by Paessler does not support the import of MIB files. The SNMP Trap Receiver sensor only considers the MIB files that PRTG includes by default.
Add Sensor
The Add Sensor dialog appears when you manually add a new sensor to a device. It only shows the setting fields that are required for creating the sensor. Therefore, you do not see all setting fields in this dialog. You can change (nearly) all settings in the sensor's Settings tab later.
Sensor Settings
Click the Settings tab of a sensor to change its settings.
Usually, a sensor connects to the IP Address or DNS Name of the parent device on which you created the sensor. See the device settings for details. For some sensors, you can explicitly define the monitoring target in the sensor settings. See below for details on available settings.
|
Sensor Name
|
Enter a meaningful name to identify the sensor. By default, PRTG shows this name in the device tree, as well as in alarms, logs, notifications, reports, maps, libraries, and tickets.
|
Parent Tags
|
Shows tags that this sensor inherits from its parent device, group, and probe. This setting is shown for your information only and cannot be changed here.
|
Tags
|
Enter one or more tags, separated by spaces or commas. You can use tags to group sensors and use tag–filtered views later on. Tags are not case sensitive. We recommend that you use the default value.
There are default tags that are automatically predefined in a sensor's settings when you add a sensor. See section Default Tags below.
You can add additional tags to the sensor if you like. Other tags are automatically inherited from objects further up in the device tree. These are visible above as Parent Tags.
It is not possible to enter tags with a leading plus (+) or minus (-) sign, nor tags with parentheses (()) or angle brackets (<>).
|
Priority
|
Select a priority for the sensor. This setting determines where the sensor is placed in sensor lists. A sensor with a top priority is at the top of a list. Choose from one star (low priority) to five stars (top priority).
|
Default Tags
snmptrapsensor
|
Listen on Port
|
Enter the number of the port on which the sensor listens for SNMP traps. The default port is 162. Enter an integer value. We recommend that you use the default value.
|
Purge Messages After
|
Define for how long PRTG stores received trap messages for analysis. Choose a period of time from the dropdown list.
|
|
Include Filter
|
Define if you want to filter traps. If you leave this field empty or use the keyword "any", the sensor processes all data. This setting is default. To include only specific types of traps, define filters using a special syntax.
For more information, see section Filter Rules.
|
Exclude Filter
|
Define which types of traps the sensor discards and does not process. To exclude specific types of traps, define filters using a special syntax.
For more information, see section Filter Rules.
|
Warning Filter
|
Define which types of traps count for the Warnings channel. To categorize received traps as warning messages, define filters using a special syntax.
For more information, see section Filter Rules.
Messages are collected until a scanning interval ends. As long as the scanning interval is running, no status change happens. By default, the sensor changes to a Warning status after a scanning interval has finished and there has at least been one warning message (and no error message) during this interval. The sensor shows a Warning at least until the succeeding scanning interval has finished. If the sensor does not receive any warning or error message in this scanning interval, its status changes to Up again with the start of the next scanning interval.
|
Error Filter
|
Define which types of traps count for the Errors channel. To categorize received traps as error messages, define filters using a special syntax.
For more information, see section Filter Rules.
Messages are collected until a scanning interval ends. As long as the scanning interval is running, no status change happens. By default, the sensor changes to a Down status after a scanning interval has finished and there has at least been one error message during this interval. The sensor shows a Down status at least until the succeeding scanning interval has finished. If the sensor does not receive any warning or error message in this scanning interval, its status changes to Up again with the start of the next scanning interval.
|
|
Primary Channel
|
Select a channel from the list to define it as the primary channel. In the device tree, the last value of the primary channel is always displayed below the sensor's name. The available options depend on what channels are available for this sensor.
You can set a different primary channel later by clicking the pin symbol of a channel on the sensor's Overview tab.
|
Graph Type
|
Define how different channels are shown for this sensor:
- Show channels independently (default): Show a graph for each channel.
- Stack channels on top of each other: Stack channels on top of each other to create a multi-channel graph. This generates a graph that visualizes the different components of your total traffic.
This option cannot be used in combination with manual Vertical Axis Scaling (available in the channel settings).
|
Stack Unit
|
This field is only visible if you enable Stack channels on top of each other as Graph Type. Select a unit from the list. All channels with this unit are stacked on top of each other. By default, you cannot exclude single channels from stacking if they use the selected unit. However, there is an advanced procedure to do so.
|
Inherited Settings
By default, all of the following settings are inherited from objects that are higher in the hierarchy and should be changed there if necessary. Often, best practice is to change them centrally in the root group settings. For more information, see section Inheritance of Settings. To change a setting for this object only, disable inheritance by clicking the button next to inherit from under the corresponding setting name. You then see the options described below.
|
Click to interrupt the inheritance. See section Inheritance of Settings for more information.
|
Scanning Interval
|
Select a scanning interval (seconds, minutes, or hours). The scanning interval determines the amount of time that the sensor waits between two scans. You can change the available intervals in the system administration on PRTG on premises installations.
|
If a Sensor Query Fails
|
Define the number of scanning intervals that the sensor has time to reach and check a device again in case a sensor query fails. Depending on the option that you select, the sensor can try to reach and check a device again several times before the sensor shows a Down status. This can avoid false alarms if the monitored device only has temporary issues. For previous scanning intervals with failed requests, the sensor shows a Warning status. Choose from:
- Set sensor to down immediately: Set the sensor to a Down status immediately after the first failed request.
- Set sensor to warning for 1 interval, then set to down (recommended): Set the sensor to a Warning status after the first failed request. If the following request also fails, the sensor shows an error.
- Set sensor to warning for 2 intervals, then set to down: Set the sensor to a Down status only after three consecutively failed requests.
- Set sensor to warning for 3 intervals, then set to down: Set the sensor to a Down status only after four consecutively failed requests.
- Set sensor to warning for 4 intervals, then set to down: Set the sensor to a Down status only after five consecutively failed requests.
- Set sensor to warning for 5 intervals, then set to down: Set the sensor to a Down status only after six consecutively failed requests.
Sensors that monitor via Windows Management Instrumentation (WMI) always wait at least one scanning interval before they show a Down status. It is not possible to immediately set a WMI sensor to a Down status, so the first option does not apply to these sensors. All other options can apply.
If you define error limits for a sensor's channels, the sensor immediately shows a Down status. No "wait" option applies.
If a channel uses lookup values, the sensor immediately shows a Down status. No "wait" options apply.
|
|
You cannot interrupt the inheritance for schedules, dependencies, and maintenance windows. The corresponding settings from the parent objects are always active. However, you can define additional settings here. They are active at the same time as the parent objects' settings.
|
Schedule
|
Select a schedule from the list. Schedules can be used to monitor for a certain time span (days or hours) every week.
You can create schedules, edit schedules, or pause monitoring for a specific time span. For more information, see section Account Settings—Schedules.
Schedules are generally inherited. New schedules are added to schedules that you already set up, so all schedules are active at the same time.
|
Maintenance Window
|
Specify if you want to set up a one-time maintenance window. During a maintenance window, the selected object and all child objects are not monitored. They are in a Paused status instead. Choose between:
- Not set (monitor continuously): No maintenance window is set and monitoring is always active.
- Set up a one-time maintenance window: Pause monitoring within a maintenance window. You can define a time span for a monitoring pause below and change it even for an active maintenance window.
To terminate an active maintenance window before the defined end date, change the time entry in Maintenance Ends to a date in the past.
|
Maintenance Begins
|
This field is only visible if you enable Set up a one-time maintenance window above. Use the date time picker to enter the start date and time of the maintenance window.
|
Maintenance Ends
|
This field is only visible if you enable Set up a one-time maintenance window above. Use the date time picker to enter the end date and time of the maintenance window.
|
Dependency Type
|
Define a dependency type. You can use dependencies to pause monitoring for an object depending on the status of a different object. You can choose from:
- Use parent: Use the dependency type of the parent object.
- Select a sensor: Use the dependency type of the parent object. Additionally, pause the current object if a specific sensor is in a Down status or in a Paused status caused by another dependency.
- Master sensor for parent: Make this sensor the master object for its parent device. The sensor influences the behavior of its parent device: If the sensor is in a Down status, the device is paused. For example, it is a good idea to make a Ping sensor the master object for its parent device to pause monitoring for all other sensors on the device in case the device cannot even be pinged. Additionally, the sensor is paused if the parent group is paused by another dependency.
To test your dependencies, select Simulate Error Status from the context menu of an object that other objects depend on. A few seconds later, all dependent objects are paused. You can check all dependencies under Devices | Dependencies in the main menu bar.
|
Dependency
|
This field is only visible if you enable Select a sensor above. Click the Search button and use the object selector to select a sensor on which the current object will depend.
|
Dependency Delay (Sec.)
|
This field is only visible if you enable Select a sensor above. Define a time span in seconds for dependency delay.
After the master sensor for this dependency comes back to an Up status, monitoring of the dependent objects is additionally delayed by the defined time span. This can prevent false alarms, for example, after a server restart, by giving systems more time for all services to start up. Enter an integer value.
This setting is not available if you set this sensor to Use parent or to be the Master sensor for parent. In this case, define delays in the parent device settings or in its parent group settings.
|
|
Click to interrupt the inheritance. See section Inheritance of Settings for more information.
|
User Group Access
|
Define the user groups that have access to the sensor. You see a table with user groups and group access rights. The table contains all user groups in your setup. For each user group, you can choose from the following group access rights:
- Inherited: Inherit the access rights settings of the parent object.
- No access: Users in this user group cannot see or edit the sensor. The sensor neither shows up in lists nor in the device tree.
- Read access: Users in this group can see the sensor and view its monitoring results. They cannot edit any settings.
- Write access: Users in this group can see the sensor, view its monitoring results, and edit its settings. They cannot edit its access rights settings.
- Full access: Users in this group can see the sensor, view its monitoring results, edit its settings, and edit its access rights settings.
For more details on access rights, see section Access Rights Management.
|
|
Click to interrupt the inheritance. See section Inheritance of Settings for more information.
|
Channel Unit Types
|
For each type of channel, define the unit in which data is displayed. If defined on probe, group, or device level, these settings can be inherited to all sensors underneath. You can set units for the following channel types (if available):
- Bandwidth
- Memory
- Disk
- File
- Custom
Custom channel types can be set on sensor level only.
|
|
Log Data to Disk
|
Define if the probe writes a logfile of the received data for debugging purposes:
- Off (recommended): Do not write additional logfiles. This is recommended for normal use cases.
- On: Write logfiles for all received data to the \Logs\debug subfolder of the PRTG data directory.
Use with caution. This option can create huge data files. Use for a short time and for debugging purposes only.
|
Filter Rules for Traps
Filter rules are used for the include, exclude, warning, and error definition fields of the SNMP Trap Receiver sensor. They are based on the following format:
field[filter]
You can use various filters that are suitable to your needs. Include and exclude filters to define which traps to monitor. Warning and error filters define how to categorize received traps. Provide these filters in the sensor settings as formulas. Formulas are fields that you can combine with boolean operators (AND, OR, NOT) and brackets.
|
|
|
source[ip]
|
Enter an IP address where the UDPs come from. IP masks and ranges are also possible.
|
source[10.0.23.50], source[10.0.23.10-50],
source[10.0.23.10/24]
|
agent[ip]
|
Enter an IP address that specifies the object that creates the SNMP trap. Only v1 is supported.
|
agent[10.0.0.1]
|
enterprise[oid]
|
Enter an OID that specifies the object that originates the trap. Only v1 is supported.
|
enterprise[1.3.6.1.4.1.2.6.182.1.2.31.1.0]
|
bindings[text]
|
Enter a substring to match all OIDs and values in the bindings.
|
bindings[ERROR],
bindings[1.3.6.1.4.1.2.6.182.1.2.31.1.0],
bindings["port blocked"]
It is not necessary to use quotation marks (") to find strings. If the string contains quotation marks that you want to include in the filter, you need to escape them with quotation marks.
|
bindings[oid,value]
|
Enter an OID and a substring to match a value in the specified OID. Separate OID and value with a comma.
|
bindings[1.3.6.1.4.1.2.6.182.1.2.31.1.0,error]
|
bindings[oid,value,mode]
|
Enter an OID, a substring, and a mode to match a value in the specified OID. Separate the OID, the value, and the mode with a comma. The mode can be:
- substring: This is the default mode that works like bindings[oid,value].
- exact: This mode enforces an exact match of a value.
- equal, greater, greaterorequal, less, or lessorequal: This interprets and compares values as numbers. It only supports integer values without extra characters and without thousands separators. Hex format is also supported.
|
bindings[1.3.6.1.4.1.2.6.182.1.2.31.1.0,error,exact]
bindings[1.3.6.1.4.1.2.6.182.1.2.31.1.0,10,equal]
|
gentrap[number]
|
Enter a number that specifies the generic trap type. Ranges are also possible.
|
gentrap[3], gentrap[2-6]
|
spectrap[number]
|
Enter a number that defines the specific trap code. Ranges are also possible.
|
spectrap[4], spectrap[0-3]
|
version[number]
|
Enter a number (1 or 2) that specifies the SNMP version.
|
version[1], version[2]
|
community[text]
|
Enter a community string for an exact, case-sensitive match.
|
community[public],
community[private]
|
Messages Tab: Review and Analyze Traps
PRTG stores received traps as common files in the \Trap Database subfolder of the PRTG data directory. To review and analyze all received messages, you can directly access the most recent data in a table list on the PRTG web interface. You can access this list via the sensor's Overview tab.
Received traps are only shown in the table on the Overview tab after an (automatic) page refresh following a sensor scan. The default value for auto refresh is 30 seconds.
For more details and further filter options, click the Messages tab of the SNMP Trap Receiver sensor. You see all received messages in a table list. On the top, you have display filter options to drill down into the data for specific events of your interest. The filters are the same as those available in the sensor settings, but you can define them without using formulas. Provide the desired parameters and PRTG automatically loads the filtered list.
Boolean operators are automatically applied to the filters in the following manner: parameters across all columns are combined with AND, and parameters within a single column are combined with OR.
The parameters entered into the filters have to exactly match the parameters in the message. They are case sensitive.
You can automatically add a filter by clicking the content of a column.
Advanced Filter Settings
You can open advanced filter settings by clicking the gear icon in the Filter row. The Advanced Filter appears in a popup window. In the text field, you can define a filter using the syntax as described in section Filter Rules for Traps.
If you provided filter parameters on the Messages tab, the advanced filter already includes them as a corresponding formula with the correct syntax. You can adjust this filter to your needs. You can also copy the automatically created and manually adjusted formula for usage in the filter fields of the sensor settings.
More
KNOWLEDGE BASE
What SNMP sensors does PRTG offer?
My SNMP sensors don't work. What can I do?
How can I show the name of a received OID in PRTG?
How can I configure sensors using speed limits to keep the status for more than one interval?
How do I test an SNMP Trap Receiver Sensor?
What placeholders can I use with PRTG?
Edit Channels
To change display settings, spike filtering, and limits, switch to the sensor's Overview tab and click the gear icon of a specific channel. For detailed information, see section Sensor Channel Settings.
Notification Triggers
Click the Notification Triggers tab to change notification triggers. For detailed information, see section Sensor Notification Triggers Settings.
Others
For more general information about settings, see section Object Settings.
Sensor Settings Overview